How to use this calculator
- 1Measure the area to insulate, for example the loft or attic floor.
- 2Enter your target R-value from your building rules or energy advice (use the unit menu for US R or m²K/W).
- 3Choose the insulation material, or enter the λ value printed on your product.
- 4Topping up a loft? Tick the box and enter the depth of the old insulation that stays.
- 5Choose the product you plan to buy — its thickness and coverage fill in together — or enter your own pack's figures.
- 6Read the thickness needed, the number of layers and the packs to buy.
The formula
- 01Thickness needed = (target R − R of old insulation) × λ
- 02R of old insulation = old depth ÷ old λ
- 03Layers = thickness needed ÷ pack thickness, rounded up
- 04R-value you get = layers × pack thickness ÷ λ
- 05Packs = area × layers × (1 + extra %) ÷ area per pack, rounded up
The R-value (thermal resistance) of a layer of insulation is its thickness divided by its thermal conductivity, λ (lambda): R = thickness ÷ λ. So the thickness you need is simply the target R-value multiplied by λ. Materials with a lower λ, such as PIR board, reach the same R-value with much less thickness than mineral wool.
Europe uses metric R-values (m²·K/W) and λ in W/(m·K); the US uses R-values in ft²·°F·h/BTU. One US R equals 0.176 m²K/W, so R-49 is about 8.6 m²K/W. US products give an R-value per inch; the calculator converts between the two.
Material λ values vary between products. For each material we use the less favourable end of the published range, so the thickness is not under-estimated. Use the value printed on your own product when you have it.
Worked example
To reach 6 m²K/W with glass mineral wool at λ 0.044 you need 264 mm of insulation.
With 150 mm rolls that is 2 layers (300 mm, giving 6.82 m²K/W). For 40 m² plus 10% extra, buy 10 packs covering 9.177 m² each.
Tips before you buy
- Lay the first layer between the ceiling joists and the second across them. This covers the joists, which would otherwise let heat escape.
- If you want to store things in the loft, use raised loft legs or a platform so boards do not squash the insulation.
- Seal gaps around loft hatches, pipes and cables before insulating — warm air leaking through them wastes heat and carries moisture into the cold loft.
- For blown insulation, fit depth rulers across the attic before blowing so you can check the settled depth everywhere.
- Packs are compressed; open them where they will be laid and let the roll recover its full thickness before judging the depth.
Frequently asked questions
What is the R-value per inch of spray foam, XPS, mineral wool and fiberglass?
Roughly, per inch: closed-cell spray foam R-5.5 to 7, PIR/polyiso R-6.5, XPS R-5 (US boards), EPS R-3.8 to 4.4, open-cell spray foam R-3.5 to 3.6, mineral (rock) wool R-3.7 to 4.2, cellulose R-3.2 to 3.8 and fiberglass batts R-3.0 to 3.4. The calculator uses the lower end of each range; enter your product's figure if you have it.
How thick should loft insulation be?
In the UK the usual recommendation for a loft is 270 mm of mineral wool, which is about R 6 m²K/W. In the US, ENERGY STAR recommends R-49 to R-60 for an uninsulated attic in most climate zones — roughly 16–20 in of fiberglass batts.
How do I convert R-value to thickness?
Multiply the R-value by the material's thermal conductivity. For R 6 m²K/W with glass wool at λ 0.044: 6 × 0.044 = 0.264 m, or 264 mm. With US R-values, divide by the R per inch: R-49 ÷ 3.0 per inch ≈ 16.3 in.
What is the difference between R-value and U-value?
R-value measures one layer's resistance to heat flow; higher is better. U-value measures how much heat passes through a whole wall, roof or floor; lower is better. Building rules in Europe often set U-values, which include all the layers of the construction.
What is a good λ (lambda) value?
Lower is better. Loft rolls are typically 0.040–0.044 W/m·K, stone wool slabs about 0.035–0.038, EPS about 0.033–0.038 and PIR boards about 0.022. The λ value is printed on European packs.
Can I put new insulation on top of old?
Usually yes, if the old insulation is dry and in good condition. Tick "Topping up old insulation" and enter its depth: its R-value is taken off your target, so only the new layer is counted. Remove anything damp or mouldy, and find the cause first.
How many rolls of loft insulation will I need?
Divide the loft floor area by the area one roll covers at your thickness — it is printed on the pack — for each layer. A 40 m² loft with rolls that cover 5 m² needs 8 rolls per layer; two layers laid crosswise need 16.
Sources
- Knauf Insulation Loft Roll 40 and 44 data sheet, June 2024 (λ 0.044; 100/150/170/200 mm: 13.885/9.177/8.014/6.840 m² per pack)
- Owens Corning R-30 unfaced fiberglass batt, 10 in, 53.33 ft² per bag
- Loose-fill insulation: settled R-value per inch — Building America Solution Center
- Energy Saving Trust: roof and loft insulation (270 mm recommended depth)
- ENERGY STAR recommended home insulation R-values
- US DOE Guide to Home Insulation (R-values of batts and boards)
- US DOE Building America: Guide to closed-cell and open-cell spray polyurethane foam (R-6 and about R-3.6 per inch)
Formulas last reviewed: September 30, 2026 ·How we check our formulas