Heat pump size calculator: what size heat pump do I need?

Estimate the heat loss of your home — or one room — on the coldest design day, and the heat pump output that covers it, in kW, BTU/h and tons. Choose how well the home is insulated and how cold it gets where you live; add hot water if the heat pump will heat that too.

1Your home

Add up the floor area of every heated room on every floor. Leave out unheated garages, lofts and cellars.

The rules of thumb are for rooms about 2.5 m (8 ft 2 in) high. Taller rooms raise the heat loss in proportion; lower rooms reduce it.

2Insulation

Your choice above fills this in: the rule-of-thumb heat loss per m² at −10 °C outside and 20 °C inside, divided by 30 (W/m²K; BTU/h per ft² per °F in US units). Change it if an energy survey gives you a better figure.

3Temperatures

The cold the heating must still beat — colder than a normal winter day, but not the record low.

4Hot water (optional)

Your results

Your results appear here

Type your measurements in the empty boxes. Still needed:

  • Heated floor area
  • Free
  • No sign-up
  • Any unit
  • PDF & CSV

What size heat pump do I need? Using the calculator

  1. 1Choose the whole home or one room, then enter the heated floor area (or the room's length and width) and the ceiling height.
  2. 2Pick how well the home is insulated — by the year it was built, or by what has been insulated since.
  3. 3Choose the indoor temperature and the design temperature where you live, or enter your own.
  4. 4Switch on hot water if the heat pump will heat that too, and read the size in kW, BTU/h and tons.

Heat pump sizing formula: heat loss from floor area and temperature

  1. 01Temperature difference = indoor temperature − outdoor design temperature
  2. 02Heat loss (W) = floor area × heat loss per m² per degree × (ceiling height ÷ 2.5 m) × temperature difference
  3. 03Heat loss per m² per degree = rule-of-thumb W/m² at −10 °C ÷ 30
  4. 04Heat pump size = heat loss + people × hot-water allowance
  5. 05BTU/h = W × 3.412; tons = BTU/h ÷ 12,000

Installers in Germany and the Netherlands start a heat pump estimate with a figure per m² of floor: about 40 W/m² for a new home, 60–100 W/m² for a partly insulated one and 100–160 W/m² for an old home without insulation (Bundesverband Wärmepumpe; Bosch). Those figures are for their climate — about −10 °C outside and 20 °C inside, a 30-degree difference — and for rooms about 2.5 m high. The calculator divides them by 30 to get the loss per degree, then multiplies by your own temperature difference and ceiling height, so the same home needs less in London (−3 °C) and more in Chicago (−20 °C).

The design temperature is not the coldest night on record but the cold the heating must still beat on all but a few hours a year: the UK figures (CIBSE Guide A, used by MCS) and the US ones (ASHRAE) are the temperatures that 99.6 % of the hours in a year are warmer than. A heat pump that covers the heat loss at that temperature keeps the home warm nearly all the time without a big backup heater.

Heat pump size example

A partly insulated 1,800 ft² home with 8 ft ceilings, kept at 70 °F inside where the design temperature is 14 °F (New York or Philadelphia), works with a 55.8 °F temperature difference.

It loses about 46,582 BTU/h at that temperature — 25.9 BTU/h per ft², or 3.88 tons (AC) — so it needs a heat pump that still gives that much heat at 14 °F.

Tips before you buy

  • Insulate and draught-proof first: every watt per m² you save makes the heat pump smaller and cheaper to run.
  • Check your radiators: a heat pump heats the water less hot than a boiler, so some rooms may need bigger radiators or underfloor heating.
  • If you heat with gas or oil now, a year of bills is a good cross-check — an installer can work back from it to the heat loss.
  • Ask for the room-by-room heat-loss calculation in writing and compare its total with this estimate.

Frequently asked questions

What size heat pump do I need for my house?

Floor area × heat loss per m² per degree × the difference between inside and the design temperature. A partly insulated 120 m² home kept at 20 °C needs about 9.7 kW where the design temperature is −10 °C (the Netherlands, much of Germany) and about 7.5 kW at −3 °C (London). A partly insulated 1,800 ft² home at 70 °F in New York (14 °F) needs about 46,600 BTU/h — close to 4 tons.

How many watts of heat pump per m² or per ft²?

At about −10 °C outside: roughly 40 W/m² for a new home, 60–100 W/m² partly insulated and 100–160 W/m² for an old home without insulation (Bundesverband Wärmepumpe) — about 13, 19–32 and 32–51 BTU/h per ft². Milder places need less and colder ones more; the calculator scales it to your design temperature.

What is the design temperature for a heat pump?

The cold the heating must still cope with. Examples: London −3.0 °C, Birmingham −5.1 °C and Glasgow −5.6 °C (MCS, from CIBSE Guide A); the Netherlands −10 °C (ISSO 51); Berlin about −11 to −13 °C (DIN/TS 12831-1); New York 12.8 °F, Chicago −5 °F and Minneapolis −14.9 °F (ASHRAE, 99.6 %).

Should I add hot water to the heat pump size?

If the heat pump also heats a hot-water cylinder, German planners add about 0.25 kW per person — 1 kW for a family of four. With an electric shower or a separate water heater, leave it out.

Is a bigger heat pump better?

No. A heat pump that is much too big switches on and off often and runs less efficiently. MCS asks for one that covers 100 % of the calculated heat loss at the design temperature; choose a model whose output at that temperature is just above your figure.